Truth table, 17 function library – Lenze 8400 HighLine User Manual
Page 1389
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
1389
17
Function library
17.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
Truth table
[17-1] Truth table for activating the pre-switch off
Identifier
Data type
Value/meaning
bRfgOut
BOOL
Control signal for ramping down the setpoint generator
• Connect this output to the bRfg0 input of the
FB.
bJog1Out
BOOL
Control signal for setting fixed speeds in the setpoint generator
• Connect this output to the bJog1 input of the
FB.
bJog2Out
BOOL
Control signal for setting fixed speeds in the setpoint generator
• Connect this output to the bJog2 input of the
FB.
Input
Function
Response in the L_NSet FB
bInputSel1
bInputSel2
FALSE
FALSE
Pre-switch off inactive
No response
• The bRfgIn input signal is directly
provided at the bRfgOut output.
• The bJogIn1 and bJogIn2 input signals are
directly output at the bJog1Out and
bJog2Out outputs.
TRUE
FALSE
The bSlowDown1 and bStop1 inputs
are evaluated.
Pre-switch off can be activated
• If the SlowDown function is activated via
the selected bSlowDown input, fixed
setpoint 2 in the setpoint generator is
activated via the bJog1Out and bJog2Out
outputs.
• If the Stop function is activated via the
selected bStop input, the bRfgOut output
is set to TRUE and hence the setpoint
generator is deactivated.
FALSE
TRUE
The bSlowDown2 and bStop2 inputs
are evaluated.
TRUE
TRUE
The bSlowDown3 and bStop3 inputs
are evaluated.