C01202 | mck: im motor/process, C01203 | mck: ig motor/position encoder, C01204 | mck: feed constant – Lenze 8400 HighLine User Manual
Page 1063: C01205 | mck: position resolution, C01202/1, C01202/2, C01203/1, C01203/2, C01204, C1202/1
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
1063
15
Parameter reference
15.2
Parameter list | C01202
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01202
C01203
C01204
C01205
Parameter | Name:
C01202 | MCK: iM motor/process
Data type: UNSIGNED_16
Index: 23373
d
= 5B4D
h
Gearbox factor - motor
• Entry of the gearbox factor as numerator/denominator ratio (numerator = motor speed and denominator =
output speed of gearbox) or from the number of teeth of the gearbox arrangement.
Setting range
(min. value | unit | max. value)
1
65535
Subcodes
Lenze setting
Info
C01202/1
1
MCK: iM: Numerator gearbox factor Z2
C01202/2
1
MCK: iM: Denominator gearbox factor Z1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01203 | MCK: iG motor/position encoder
Data type: UNSIGNED_16
Index: 23372
d
= 5B4C
h
Gearbox factor - position encoder
• Entry of the gearbox factor as numerator/denominator ratio, with numerator = motor speed and denominator
= position encoder speed.
Setting range
(min. value | unit | max. value)
1
65535
Subcodes
Lenze setting
Info
C01203/1
1
MCK: iG: Numerator (motor speed)
C01203/2
1
MCK: iG: Denominator (encoder speed)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01204 | MCK: Feed constant
Data type: INTEGER_32
Index: 23371
d
= 5B4B
h
The feed constant corresponds to the movement of the machine during one revolution of the gearbox output shaft.
• The value is entered in application units referred to one revolution.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0001
units/rev.
214748.3647 360.0000 units/rev.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01205 | MCK: Position resolution
Data type: INTEGER_32
Index: 23370
d
= 5B4A
h
Display of the number of increments corresponding to one unit.
• 1 motor revolution ≡ 65536 increments
Display range
(min. value | unit | max. value)
0.0000
Incr./unit
214748.3647
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000