8.12.2.3
Switching thresholds
Upper speed threshold for brake release:
Switching threshold (
) + hysteresis for release (
Lower speed threshold for brake application:
Switching threshold (
) - hysteresis for application (
Tip!
The lower speed threshold for brake application should be set to approximately 5 ... 20 % of
the maximum speed to minimise the wear of the brake and provide for an optimum brake
reaction by a low grinding of the brake.
Related topics:
Process when brake is released
Stop!
Do not set the lower speed threshold for closing the brake too high to prevent excessive
wear of the brake!