1 parameter setting, Parameter setting, 8basic drive functions (mck) – Lenze 8400 HighLine User Manual
Page 547
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
547
8
Basic drive functions (MCK)
8.6
Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.6.1
Parameter setting
Parameterisation dialog in the »Engineer«
Short overview of parameters for "Referencing" operating mode:
Parameter
Info
Lenze setting
Value Unit
MCK: Ref. setting
(from version 14.00.00)
Bit coded
MCK: Homing mode
12: >_Lp
MCK: Ref. initial speed
720.0000 unit/s
MCK: Ref. initial acceleration
720.0000 unit/s2
MCK: Ref. search speed
180.0000 unit/s
MCK: Ref. search acceleration
720.0000 unit/s2
MCK: Ref. S-ramp time
0.000 s
MCK: Ref. M limit mode 14/15
10.00 %
MCK: Ref. waiting time mode 14/15
100 ms
MCK: Ref. offset reference degree
0.0000 unit
MCK: Ref. home position
0.0000 unit
MCK: Ref. sequence profile
0
MCK: Positive SW limit position
0.0000 units
MCK: Negative SW limit position
0.0000 units
MCK: Ref. TP signal source
(from version 06.00.00)
0: No TP
MCK: Set.Ref. signal source
(from version 06.00.00)
0: No TP