7technology applications – Lenze 8400 HighLine User Manual
Page 440
7
Technology applications
7.4
TA "Table positioning"
440
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
bGPLogicIn1
bGPLogicIn2
bGPLogicIn3
BOOL
: Input signals
• The logic operation is selected in
• The result is output at output bGPLogicOut.
nGPCompareIn1_a
nGPCompareIn2_a
INT
: Input signals
• The comparison operation is selected in
.
• Hysteresis and window size can be set in
• If the comparison statement is true, the output bGPCompareOut will be set to
TRUE.
bGPDFlipFlop_InD
bGPDFlipFlop_InClk
bGPDFlipFlop_InClr
BOOL
: Input signals
• Data, clock and reset input
bGPCounter1ClkUp
BOOL
: Clock input
• With each edge, the module counts up by "1".
• Only FALSE-TRUE edges are evaluated.
Note: The static state "1" is not permissible at this input.
bGPCounter1ClkDown
BOOL
: Clock input
• With each edge, the module counts down by "1".
• Only FALSE-TRUE edges are evaluated.
Note: The static state "1" is not permissible at this input.
bGPCounter1Load
BOOL
: Loading input
• The input has the highest priority.
TRUE Accept the starting value wGPCounter1LdVal.
wGPCounter1LdVal
WORD
: Starting value
• Assigned value is internally interpreted as "INT" data type (-32767 ... +32767), i.e.
the most significant bit determines the sign.
wGPCounter1CmpVal
WORD
: Comparison value
• Assigned value is internally interpreted as "INT" data type (-32767 ... +32767), i.e.
the most significant bit determines the sign.
Free inputs
The following inputs can freely be interconnected on the application level.
The signals can be transferred from the I/O level to the application level via these inputs.
bFreeIn1 ... bFreeIn8
BOOL
Free inputs for digital signals
wFreeIn1 ... wFreeIn4
WORD
Free inputs for 16-bit signals
dnFreeIn1_p ... dnFreeIn2_p
DINT
Free inputs for 32-bit signals
Identifier
Data type
Value/meaning
wDriveControlStatus
WORD
Status word of the controller
• The status word contains information on the currents status of the drive
controller.
• See the "
" subchapter of the chapter on device
control for a detailed description of the bit assignment.
wStateDetermFailNoLow
WORD
Display of the status determining error (LOW word)
wStateDetermFailNoHigh
WORD
Display of the status determining error (HIGH word)
bDriveFail
BOOL
TRUE Drive controller in error status.
• "
" device status is active.
Identifier
Data type
Information/possible settings