C00998 | slpsm: filter time rotor position, C00999 | slpsm: pll gain, C00998/1 – Lenze 8400 HighLine User Manual
Page 1032: C00998/2, Value, C00999, 15 parameter reference
15
Parameter reference
15.2
Parameter list | C00998
1032
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00998
C00999
Parameter | Name:
C00998 | SLPSM: Filter time rotor position
Data type: INTEGER_16
Index: 23577
d
= 5C19
h
From version 10.00.00
Sensorless control for synchronous motors (SLPSM)
Setting range
(min. value | unit | max. value)
0.5
ms
20.0
Subcodes
Lenze setting
Info
C00998/1
3.0 ms
: Filter time rotor position
C00998/2
5.0 ms
: Filter time actual speed value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00999 | SLPSM: PLL gain
Data type: INTEGER_16
Index: 23576
d
= 5C18
h
From version 10.00.00
Sensorless control for synchronous motors (SLPSM)
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
1000 400 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1