C00002 | device command, C00002/31, C00002/32 – Lenze 8400 HighLine User Manual
Page 797: C00002/33, C00002/29, C00002/30, Via the, C00002/16, Device command, C00002/28

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
797
15
Parameter reference
15.2
Parameter list | C00002
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00002
Parameter | Name:
C00002 | Device command
Data type: UNSIGNED_8
Index: 24573
d
= 5FFD
h
Note:
• Before switching off the supply voltage after a device command has been executed, check the successful
execution of the device command via the status display in
• Before activating device commands by a master control, wait for the "Ready" signal of the controller.
• The device will reject a write process to C00002/x if the value is >1 and issue an error message.
:
Selection list
0 Off / ready
1 On / start
4 Action cancelled
5 No access
6 No access controller inhibit
20 20% working
40 40% working
60 60% working
80 80% working
Subcodes
Lenze setting
Info
C00002/1
0: Off / ready
Load Lenze setting
• All parameters are reset to the Lenze setting.
• Only possible when the controller is inhibited.
C00002/2
0: Off / ready
Reserved
C00002/3
0: Off / ready
Reserved
C00002/4
0: Off / ready
Reserved
C00002/5
0: Off / ready
Reserved
C00002/6
0: Off / ready
Load all parameter sets
• All parameter sets are loaded by the memory module.
• Only possible when the controller is inhibited.
C00002/7
0: Off / ready
Reserved
C00002/8
0: Off / ready
Reserved
C00002/9
0: Off / ready
Reserved
C00002/10
0: Off / ready
Reserved
C00002/11
0: Off / ready
Save all parameter sets
• All parameter sets are saved to the memory module
safe against mains failure.
C00002/12
0: Off / ready
Reserved
C00002/13
0: Off / ready
Reserved
C00002/14
0: Off / ready
Reserved
C00002/15
0: Off / ready
Reserved
C00002/16
1: On / start
Enable controller
1 ≡ Enable controller
0 ≡ Inhibit controller