_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01059
C01060
C01061
Parameter | Name:
C01059 | L_PosCtrlLin 1-2: Positioning behaviour
Data type: UNSIGNED_8
Index: 23516
d
= 5BDC
h
From version 11.00.00
Selection list
0 dnOut_p = 0
1 dnOut_p/nOut_v follow dnAct_p
2 dnOut_p/nOut_v follow dnSet_p
3 dnOut_p/nOut_v follow dnAct_p
(without limitation)
Subcodes
Lenze setting
Info
C01059/1
0: dnOut_p = 0
: Positioning behaviour
C01059/2
0: dnOut_p = 0
: Positioning behaviour
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01060 | L_PosCtrlLin 1-2: Ramps
Data type: INTEGER_32
Index: 23515
d
= 5BDB
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
0.010
s
130.000
Subcodes
Lenze setting
Info
C01060/1
1.000 s
: Deceleration of set position
C01060/2
1.000 s
: Acceleration ramp
C01060/3
1.000 s
: Deceleration ramp
C01060/4
1.000 s
: Deceleration of set position
C01060/5
1.000 s
: Acceleration ramp
C01060/6
1.000 s
: Deceleration ramp
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01061 | L_PosCtrlLin 1-2: Traversing speeds
Data type: INTEGER_16
Index: 23514
d
= 5BDA
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
-15000
rpm
15000
Subcodes
Lenze setting
Info
C01061/1
199 rpm
: Forward motion
C01061/2
199 rpm
: Return motion
C01061/3
199 rpm
: Forward motion
C01061/4
199 rpm
: Return motion
Read access Write access CINH PLC STOP No transfer COM MOT