Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
93
3
Commissioning
3.10
PC manual control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.10.3
Set/reset home position
The measuring system in the machine is selected by means of homing and the 0 position is set
within the possible physical travel range.
The changeover to the "Homing" operating mode is effected by selecting the option of the same
name on the Positioning tab:
How to set the reference manually with standing drive:
Click the Set reference button.
The current actual position in the machine measuring system now corresponds to the
home position set in
(Lenze setting: 0.0000 units).
Detailed information on the "Homing" operating mode is provided in chapter "Basic
drive functions" in subchapter "
Stop!
If you set the reference with PC manual control, the drive is referenced with it.
If another home position is used for normal operation:
Click the Cancel reference button and reset the status signals HomPosAvailable and
HomePosDone in the MCK status word in order that no mechanical problems can occur
during normal operation.
• Setpoints and actual positions remain untouched until a renewed reference setting or
homing.