2 operating mode change with profile number, Operating mode change with profile number, 8basic drive functions (mck) – Lenze 8400 HighLine User Manual
Page 518
![background image](/manuals/566310/518/background.png)
8
Basic drive functions (MCK)
8.3
MCKInterface
518
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
SetProfilPosition at position change
If bit 3 is set in
, the setpoint positions at the MCKInterface are automatically accepted into
the profile with the applied profile number if a change of data is detected at the corresponding
input for the setpoint position.
• If the "0: dnPosOut_p=dnPosIn_p" mode has been set in
for converting the position,
automatic acceptance is executed if the incremental position selection at the dnPosIn_p input
was changed.
• If another mode (>0) has been set in
, automatic acceptance is executed if the
incremental position selection at the wPosUnitsLW and wPosUnitsHW inputs was changed.
•
From version 11.00.00
for the position change.
PosExecute at position change
(from version 11.00.00)
If bit 4 is set in
, an automatic "PosExecute" takes place if the incremental position selection
changes and this change is higher than set in the hysteresis for position change (
).
If the selection is made in units, so that in a first step it has to be converted into increments, and if
this automatic function is then activated, the "PosExecute" will only be created automatically when
the internal conversion is completed (bPosSetDataValid).
Tip!
This option serves to start travel requests very easily by simply defining the new target
position.
8.3.1.2
Operating mode change with profile number
One of the operating modes of the LS_MotionControlKernel system block can be assigned to the
positioning profiles via the four subcodes of
:
• When a changeover to the corresponding profile is carried out, the set operating module is
requested at the same time.
• In the case of the setting "0: No change", the operating mode is not changed when the profile
changeover occurs. Instead, the operating mode requested "from outside" via the
is applicable.
Parameter
Info
Lenze setting
Operating mode if profile 0 is selected
Speed follower
Operating mode if profile 1 is selected
Homing
Operating mode if profile 2 is selected
Manual jog
Operating mode if profile 3 ... 15 is selected
Positioning