C01234 | mck: manual jog breakpoints, C01235 | mck: manual jog waiting times, C01236 | mck: speed follower – Lenze 8400 HighLine User Manual
Page 1074: C01235/1, C01234/1, C01234/2, C01234/3, C01234/4, Waiting time 2nd speed (lenze setting, C01236/1
15
Parameter reference
15.2
Parameter list | C01234
1074
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01234
C01235
C01236
Parameter | Name:
C01234 | MCK: Manual jog breakpoints
Data type: INTEGER_32
Index: 23341
d
= 5B2D
h
Breakpoint positions for manual jog
• The drive stops at the parameterised positions if these are located in the manual jog direction and the
approaching of the breakpoints is switched on in
via bit 0.
Setting range
(min. value | unit | max. value)
-214748.3647
unit
214748.3647
Subcodes
Lenze setting
Info
C01234/1
0.0000 unit
Manual jog: Breakpoint 1
C01234/2
0.0000 unit
Manual jog: Breakpoint 2
C01234/3
0.0000 unit
Manual jog: Breakpoint 3
C01234/4
0.0000 unit
Manual jog: Breakpoint 4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01235 | MCK: Manual jog waiting times
Data type: UNSIGNED_16
Index: 23340
d
= 5B2C
h
Waiting times for manual jog
Setting range
(min. value | unit | max. value)
0.000
s
65.000
Subcodes
Lenze setting
Info
C01235/1
5.000 s
Manual jog: Waiting time 2nd speed
• Time after which the first manual speed (
) is
accelerated to the second manual speed (
).
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01236 | MCK: Speed follower
Data type: INTEGER_32
Index: 23339
d
= 5B2B
h
Speeds for position follower
Setting range
(min. value | unit | max. value)
-214748.3647
units/s
214748.3647
Subcodes
Lenze setting
Info
C01236/1
360.0000 units/s
PosFollower: Sync. speed
• Synchronisation speed for approaching the setpoint
position of the master.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000