V/f characteristic control - energy-saving (VFCplusEco)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.5.4
Optimising the control mode
The V/f characteristic control - energy-saving (VFCplus) is generally ready for operation. It can be
adapted subsequently by adapting the characteristic and/or the drive behaviour.
Adapting characteristic
For the linear characteristic as part of the V/f characteristic control - energy-saving (VFCplusEco), it
is also possible (like in case of the standard V/f characteristic control) to match its curve to different
load profiles or motors by adapting the V/f base frequency (
min
boost (
).
Adapting the V/f base frequency
Adapting drive behaviour
• Limitation of the maximum current by a current limitation controller (e.g. to prevent the motor
from stalling or to limit to the maximally permissible motor current).
• Adaptation of the field frequency by a load-dependent slip compensation (improved speed
accuracy for systems without feedback).
•
Improving the behaviour at high dynamic load changes
•
Adapting the slope limitation for lowering the Eco function
•
Optimising the cos/phi controller
Torque limitation
Limit the torque to a lower value.
Note!
Following successful motor parameter identification, the V/f base frequency (
and the V
min
boost (
) as well as the slip constant for slip compensation (
)
are calculated automatically.
From version 12.00.00
onwards:
• Following successful motor parameter identification, the gain of the Imax controller
(
) is calculated automatically.
• If these parameters are not to be calculated, bit 4 of
must be set to "1".
• Following successful motor parameter identification, other controller parameters
(
,
) can be calculated automatically.
• If these parameters are to be calculated, bit 6 of
must be set to "6".