C02236 | ls_writeparamlist: rated motor speed, C02237 | ls_writeparamlist: rated motor current, C02234/1 – Lenze 8400 HighLine User Manual
Page 1106: C02234/2, C02234/3, C02234/4, C02236/1, C02236/2, C02236/3, C02236/4
15
Parameter reference
15.2
Parameter list | C02234
1106
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02234
C02236
C02237
Parameter | Name:
C02234 | LS_WriteParamList: Motor stator leakage inductance
Data type: UNSIGNED_16
Index: 22341
d
= 5745
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
mH
650.00
Subcodes
Lenze setting
Info
C02234/1
3.50 mH
: c85_val1
C02234/2
3.50 mH
: c85_val2
C02234/3
3.50 mH
: c85_val3
C02234/4
3.50 mH
: c85_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02236 | LS_WriteParamList: Rated motor speed
Data type: UNSIGNED_16
Index: 22339
d
= 5743
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
50
rpm
60000
Subcodes
Lenze setting
Info
C02236/1
1460 rpm
: c87_val1
C02236/2
1460 rpm
: c87_val2
C02236/3
1460 rpm
: c87_val3
C02236/4
1460 rpm
: c87_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02237 | LS_WriteParamList: Rated motor current
Data type: UNSIGNED_16
Index: 22338
d
= 5742
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.20
A
320.00
Subcodes
Lenze setting
Info
C02237/1
21.00 A
: c88_val1
C02237/2
21.00 A
: c88_val2
C02237/3
21.00 A
: c88_val3
C02237/4
21.00 A
: c88_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100