C00585 | resp. to motor overtemp. ptc, C00586 | resp. to open circuit htl encoder, C00588 | resp. to max. speed at switching freq – Lenze 8400 HighLine User Manual
Page 919: C00586, C00585, Is activated, Tting, Fault"), mo, C00582, In the lenze setting, no

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
919
15
Parameter reference
15.2
Parameter list | C00582
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00582
C00585
C00586
C00588
Parameter | Name:
C00582 | Resp. to heatsink temp. > shutdown temp. -5°C
Data type: UNSIGNED_8
Index: 23993
d
= 5DB9
h
Response if the heatsink temperature has reached the switch-off temperature threshold.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00585 | Resp. to motor overtemp. PTC
Data type: UNSIGNED_8
Index: 23990
d
= 5DB6
h
Response to motor overtemperature
• The motor temperature is measured by means of a PTC thermistor at terminal X106.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00586 | Resp. to open circuit HTL encoder
Data type: UNSIGNED_8
Index: 23989
d
= 5DB5
h
Response to encoder feedback system failure or encoder feedback system track failure due to open circuit
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00588 | Resp. to max. speed at switching freq.
Data type: UNSIGNED_8
Index: 23987
d
= 5DB3
h
Response if the maximum speed for the set inverter switching frequency is reached (
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1