C02221 | ls_writeparamlist: ti speed controller, C02221/1, C02221/2 – Lenze 8400 HighLine User Manual
Page 1101: C02221/3, C02221/4, C02221/5, C02221/6, C02221/7, C02221/8, C02221/9
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
1101
15
Parameter reference
15.2
Parameter list | C02221
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02221
C02222
Parameter | Name:
C02221 | LS_WriteParamList: Ti speed controller
Data type: UNSIGNED_16
Index: 22354
d
= 5752
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.0
ms
6000.0
Subcodes
Lenze setting
Info
C02221/1
100.0 ms
: c71_s1_val1
C02221/2
100.0 ms
: c71_s1_val2
C02221/3
100.0 ms
: c71_s1_val3
C02221/4
100.0 ms
: c71_s1_val4
C02221/5
50.0 ms
: c71_s2_val1
C02221/6
50.0 ms
: c71_s2_val2
C02221/7
50.0 ms
: c71_s2_val3
C02221/8
50.0 ms
: c71_s2_val4
C02221/9
100.0 ms
: c71_s3_val1
C02221/10
100.0 ms
: c71_s3_val2
C02221/11
100.0 ms
: c71_s3_val3
C02221/12
100.0 ms
: c71_s3_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C02222 | LS_WriteParamList: SC: Tdn speed controller
Data type: UNSIGNED_16
Index: 22353
d
= 5751
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
ms
3.00
Subcodes
Lenze setting
Info
C02222/1
0.00 ms
: c72_val1
C02222/2
0.00 ms
: c72_val2
C02222/3
0.00 ms
: c72_val3
C02222/4
0.00 ms
: c72_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100