8basic drive functions (mck) – Lenze 8400 HighLine User Manual
Page 523
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
523
8
Basic drive functions (MCK)
8.4
Basic settings
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Short overview of machine parameters:
After the machine parameters have been entered, the drive controller sends back application-
relevant data via the following display parameters:
Parameter
Info
Lenze setting
Value Unit
Mounting direction: Motor
0: Not inverted
iM: Nominator of gearbox factor Z2
1
iM: Denominator of gearbox factor Z1
1
Mounting direction: Position encoder
0: Not inverted
iG: Numerator (motor speed)
1
iG: Denominator (encoder speed)
1
Axis data: Axis cycle
Activation of the modulo measuring system
0.0000 units
Axis data: Feed constant
360.0000 units/rev.
Appl.: Reference speed
1500 rpm
Parameter
Info
Lenze setting
Value Unit
Max. traversing speed 100%_C11
• Is used for orientation when the velocity is being set in
the profile sets.
- units/s
Axis data: Position resolution
• Is needed for the incremental specification of positions.
- incr/unit
MCK: Positioning accuracy
• Theoretical accuracy during positioning with account
being taken of the machine data and encoder data.
- units
Maximum torque
- Nm
MCK: Max. traversing distance
- units
Highlighted in grey = display parameter