C00507 | current password protection, C00507/1, 15 parameter reference – Lenze 8400 HighLine User Manual
Page 909
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
909
15
Parameter reference
15.2
Parameter list | C00507
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00507
Parameter | Name:
C00507 | Current password protection
Data type: UNSIGNED_16
Index: 24068
d
= 5E04
h
From version 06.00.00
Display of the currently active device access protection (password protection and device personalisation)
Note:
As the password protection can be configured individually for each single communication channel
from version
15.00.00
bit 1 and bit 2 indicate the active protection always with regard to the communication channel used.
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Only access to user menu
1 ≡The menus in the keypad are reduced. Only the user
menu can be used to change parameters.
Bit 1 Parameter write protection
1 ≡ The currently used communication channel cannot
be used to write into write/read parameters.
Bit 2 Parameter read protection
1 ≡ The currently used communication channel cannot
be used to read write/read parameters.
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15 Memory module binding on
1 ≡ Device personalisation is active. All write/read
actions between controller and memory module are only
executed if both components have the same binding ID.
Subcodes
Info
C00507/1
Password protection - all communication channels
Read access Write access CINH PLC STOP No transfer COM MOT