_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2c07
11271
9437191
PS07: Invalid memory module par. set
Fault
-
0x6300
0x2c08
11272
9437192
PS08: Invalid device par.
Fault
-
0x6300
0x2c09
11273
9437193
PS09: Invalid par. format
Fault
-
0x6300
0x2c0a
11274
9437194
PS10: Memory module binding invalid
Fault
-
0x17cd
6093
8061133
Sd3: Feedback system open circuit
Fault
0x7300
0x17c8
6088
8061128
Sd10: Speed limit for feedback system 12
Fault
0x7300
0x17c9
6089
8061129
Sd11: Speed limit for feedback system 67
Fault
0x7300
0x0b02
2818
7274498
Su02: One mains phase is missing
Warning
0x3000
0x0b03
2819
7274499
Su03: Too frequent mains switching
Fault
-
0x3000
0x0b04
2820
7274500
Su04: CU Insufficiently Supplied
Warning
-
0x3000
0x0b06
2822
7274502
Su06: Mains input overload
Fault
-
0x3000
Freely configurable user error messages (see
25600
dec
+
User error 1
No Reaction
0x6200
25856
dec
+
User error 2
No Reaction
0x6200
26112
dec
+
User error 3
No Reaction
0x6200
26368
dec
+
User error 4
No Reaction
0x6200
26624
dec
+
User error 5
No Reaction
0x6200
26880
dec
+
User error 6
No Reaction
0x6200
27136
dec
+
User error 7
No Reaction
0x6200
27392
dec
+
User error 8
No Reaction
0x6200
* Only the lower 8 bits of the adjustable error ID (
) can be used.
Error number
Display in
Error message
Response
(Lenze setting)
can be set in CAN
Emergency
Error Code
32 bits
16 bits
hex
16 bits
dec
C00162/1