C00940 | l_convw numerator, C00941 | l_convw denominator, C00942 | l_convw conversion method – Lenze 8400 HighLine User Manual
Page 1021: 15 parameter reference
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
1021
15
Parameter reference
15.2
Parameter list | C00940
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00940
C00941
C00942
Parameter | Name:
C00940 | L_ConvW numerator
Data type: INTEGER_16
Index: 23635
d
= 5C53
h
From version 04.00.00
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C00940/1
1
: Numerator
C00940/2
1
: Numerator
C00940/3
1
: Numerator
C00940/4
1
: Numerator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00941 | L_ConvW denominator
Data type: INTEGER_16
Index: 23634
d
= 5C52
h
From version 04.00.00
Setting range
(min. value | unit | max. value)
1
32767
Subcodes
Lenze setting
Info
C00941/1
1
: Denominator
C00941/2
1
: Denominator
C00941/3
1
: Denominator
C00941/4
1
: Denominator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00942 | L_ConvW conversion method
Data type: UNSIGNED_8
Index: 23633
d
= 5C51
h
From version 04.00.00
Selection list
0 no conversion
1 from [%] into [incr./ms]
2 from [incr./ms] into [%]
3 Factors signed
4 Factors unsigned
Subcodes
Lenze setting
Info
C00942/1
0: No conversion
: Conversion method
C00942/2
0: No conversion
: Conversion method
C00942/3
0: No conversion
: Conversion method
C00942/4
0: No conversion
: Conversion method
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1