5 keypad, Keypad, 7technology applications – Lenze 8400 HighLine User Manual
Page 386: 2 ta "actuating drive speed" 386

7
Technology applications
7.2
TA "Actuating drive speed"
386
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.2.3.5
Keypad
Connection
Assignment
Connection
Assignment
X101/NC-NO
LA_NCtrl.bDriveFail
X5/RFR
LA_NCtrl.bFailReset
X3/A1U
-
X5/DI1
-
X3/A1I
-
X5/DI2
-
X3/A2U
-
X5/DI3
-
X3/A2I
-
X5/DI4
-
X3/O1U
LA_NCtrl.nMotorSpeedAct_a *
X5/DI5
-
X3/O1I
-
X5/DI6
-
X3/O2U
-
X5/DI7
-
X3/O2I
-
* 10 V ≡ 100 % reference speed (
X107/BD1
-
X4/DO1
LA_NCtrl.bDriveReady
X107/BD2
-
X4/DO2
-
X4/DO3
-
X4
24B
24O
GB
DO1
BD2
DO3
GO
BD1
DO2
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
Quick commissioning
SAVE
Par1 Quick commissioning
Terminals
Keypad
SAVE
Par1 8400 HighLineC
User - Menu
Logbook
Go to param
Quick commissioning
C2/1
C7
C728
C11
C12
C13
C15
C16
C22
C87
C89
C39/1
C727/3
C727/4
C51
C54
+
=
CG
CL
CH
X1
X5
X107
Engineer:
Keypad:
Actual speed value
Controller enable
/ reset error
DriveReady
External
supply
24 V DC
All parameters
Quick commissioning
Terminal
Keypad
DriveFail