Parameter reference
15.2
Parameter list | C00400
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00400
C00401
Parameter | Name:
C00400 | LS_PulseGenerator
Data type: UNSIGNED_16
Index: 24175
d
= 5E6F
h
Time setting of the pulse to be output by the SB
Note:
The real length of the low or high level at the bSquareWave output is always 1 ms higher than set here in subcode
1 or 2. If "0 ms" is set, a level with a length of 1 ms is created length, for instance, and if "1000 ms" is set, a level with
a length of 1001 ms is created.
Setting range
(min. value | unit | max. value)
0
ms
60000
Subcodes
Lenze setting
Info
C00400/1
1000 ms
Length of the low level (break) + 1 ms
C00400/2
1000 ms
Length of the high level + 1 ms
C00400/3
100 ms
From version 06.00.00
Delay time for status signal bFirstCycleDone
• The bFirstCycleDone status signal is set to TRUE when
the first task cycle is complete and the time set here
has expired.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00401 | CANxInOut: Inversion
Data type: UNSIGNED_16
Index: 24174
d
= 5E6E
h
From version 02.00.00
This parameter serves to invert the control/status bits of the CAN port blocks.
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Active
Bit set = bit is inverted
... ...
Bit 15 Active
Subcodes
Lenze setting
Info
C00401/1
0x0000
Inversion of LP_CanIn1.bCtrl1_B0...15
C00401/2
0x0000
Inversion of LP_CanOut1.bState1_B0...15
C00401/3
0x0000
Inversion of LP_CanIn2.bIn1_B0...15
C00401/4
0x0000
Inversion of LP_CanOut2.bOut1_B0...15
C00401/5
0x0000
Inversion of LP_CanIn3.bIn1_B0...15
C00401/6
0x0000
Inversion of LP_CanOut3.bOut1_B0...15
C00401/7
0x0000
Inversion of LP_CanIn4.bIn1_B0...15
•
From version 15.00.00
C00401/8
0x0000
Inversion of LP_CanOut4.bOut1_B0...15
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT