C01353 | acdrive: setpoint scaling, C01469 | l_mfail: vp, C01470 | l_mfail: tn – Lenze 8400 HighLine User Manual
Page 1092: C01353/1, Ac drive attri, C01353/2, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C01353
1092
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01353
C01469
C01470
Parameter | Name:
C01353 | ACDrive: Setpoint scaling
Data type: INTEGER_8
Index: 23222
d
= 5AB6
h
From version 13.00.00
Actuating drive speed (AC Drive Profil): Scaling of the speed and torque values
Setting range
(min. value | unit | max. value)
-128
127
Subcodes
Lenze setting
Info
C01353/1
0
ACDrive: Speed scaling
C01353/2
0
ACDrive: Torque scaling
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01469 | L_MFail: Vp
Data type: UNSIGNED_16
Index: 23106
d
= 5A42
h
Setting range
(min. value | unit | max. value)
0.001
31.000
Subcodes
Lenze setting
Info
C01469/1
1.000
: Vp
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01470 | L_MFail: Tn
Data type: UNSIGNED_16
Index: 23105
d
= 5A41
h
Setting range
(min. value | unit | max. value)
1
ms
60000
Subcodes
Lenze setting
Info
C01470/1
20 ms
: U DC-bus controller reset time
C01470/2
20 ms
: Acceleration time
C01470/3
20 ms
: Retrigger time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1