15 parameter reference – Lenze 8400 HighLine User Manual
Page 798

15
Parameter reference
15.2
Parameter list | C00002
798
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00002/17
0: Off / ready
Activate quick stop
1 ≡ Activate quick stop
0 ≡ Deactivate quick stop
Activate/deactivate quick stop
C00002/18
0: Off / ready
Reserved
C00002/19
0: Off / ready
Reset error
• After the reset (acknowledgement) of the current
error, further errors may be pending which must also
be reset.
• The status determining error is displayed in
.
• The current error is displayed in
Error messages of the operating system
C00002/20
0: Off / ready
Reserved
C00002/21
0: Off / ready
Delete logbook
• All entries in the logbook of the controller are deleted.
• In the logbook, information on the error history is
saved.
C00002/22
0: Off / ready
Reserved
C00002/23
0: Off / ready
Motor parameter identification
• This device command serves to carry out automatic
motor parameter identification.
• The device command is only executed when the drive
controller is in the "SwitchedOn" status.
• In order to identify the motor parameters, the
controller must be enabled after this device
command.
•
From version 10.00.00 onwards
, the identification
mode can be selected in
.
Automatic motor parameter identification
C00002/24
0: Off / ready
Reserved
C00002/25
0: Off / ready
Reserved
C00002/26
0: Off / ready
CAN reset node
• Reinitialise "CAN on board" interface.
• Required when changing the baud rate, node address,
or identifiers.
C00002/27
0: Off / ready
Device search function
•
From version 06.00.00
• This device command serves to optically locate a
controller connected online (e.g. for maintenance
work).
C00002/28
0: Off / ready
Check MasterPin
•
From version 06.00.00
Unlocking the controller with a MasterPin
C00002/29
0: Off / ready
Set binding ID
•
From version 06.00.00
C00002/30
0: Off / ready
Delete binding ID
•
From version 06.00.00
C00002/31
0: Off / ready
Set password
•
From version 06.00.00
Parameter | Name:
C00002 | Device command
Data type: UNSIGNED_8
Index: 24573
d
= 5FFD
h