Parameter change-over

14.4

Internal interfaces | System block "LS_WriteParamList"

788

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Identifier

Data type

Value/meaning

bDone

BOOL

"Writing of the parameter list completed" status signal

• The output is automatically reset to FALSE if writing via bExecute is activated

again.

TRUE Writing of the parameter list successfully completed.

FALSE The FALSE status can have the following meanings:

1.There is no active writing of the parameter list.

2.Writing of the parameter list has not been completed yet.

3.An error has occurred (if bFail = TRUE).

bFail

BOOL

"Error" status

TRUE An error has occurred (group signal).

• See display parameter

(C01083

) for details.