C00630 | l_limit 1-2: min/max, 15 parameter reference – Lenze 8400 HighLine User Manual
Page 938
![background image](/manuals/566310/938/background.png)
15
Parameter reference
15.2
Parameter list | C00630
938
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00630
C00622/7
0: Not connected
: dnDis7_p
Display of 32-bit signal 7
C00622/8
0: Not connected
: dnDis8_p
Display of 32-bit signal 8
C00622/9
0: Not connected
: dnOut34_p
CAN1 output: Data words 3 + 4
C00622/10
0: Not connected
: dnOut34_p
CAN2 output: Data words 3 + 4
C00622/11
0: Not connected
: dnOut34_p
CAN3 output: Data words 3 + 4
C00622/12
0: Not connected
: dnOut34_p
MCI output: Data words 3 + 4
C00622/13
0: Not connected
: dnPosIn12_Set_p
Frequency input DI1/DI2: Starting value for angle
integrator
C00622/16
0: Not connected
: dnIn1
Retain data: 32-bit input value 1
C00622/17
0: Not connected
: dnIn2
Retain data: 32-bit input value 2
C00622/18
0: Not connected
: dnIn3
Retain data: 32-bit input value 3
C00622/19
0: Not connected
: dnIn4
Retain data: 32-bit input value 4
C00622/25
0: Not connected
: dnOut34_p
CAN4 output: Data words 3 + 4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00622 | System connection list: Angle
Data type: UNSIGNED_16
Index: 23953
d
= 5D91
h
Parameter | Name:
C00630 | L_Limit 1-2: Min/Max
Data type: INTEGER_16
Index: 23945
d
= 5D89
h
Setting the limits
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00630/1
-199.99 %
: Min.Limit
C00630/2
199.99 %
: Max.Limit
C00630/3
-199.99 %
: Min.Limit
C00630/4
199.99 %
: Max.Limit
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100