4 manual jog, Manual jog, 3commissioning – Lenze 8400 HighLine User Manual
Page 94
3
Commissioning
3.10
PC manual control
94
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.10.4
Manual jog
In the "Manual jog" mode, the drive can be traversed manually in a clockwise or anticlockwise
direction.
The change to the "Manual jog" mode can be made by selecting the correspondent option on the
Positioning tab:
• The profile parameters stored in the parameter set for the basic "manual jog" function are used:
How to traverse the drive manually in inching mode:
1. If the controller is still inhibited, enable the controller via the Enable controller button.
• Please observe that the controller will not be enabled if other sources of controller
inhibit (e.g. terminal RFR) are active.
If the controller is in the "OperationEnabled" device status:
2. Click << Left or Right >> (and keep it pressed) to traverse the drive in the corresponding
direction of rotation.
You can find detailed information on the "Manual jog" mode in the chapter entitled
"Basic drive functions" in the subchapter "
Parameter
Lenze setting
Info
Value Unit
Speed 1
(
360.0000 units/s
Manual jog speed
Acceleration
(
720.0000 units/s
2
For accelerating and decelerating, different values can
be set so that smooth starting and quick stopping of the
drive can be implemented.
Delay
(
720.0000 units/s
2
S-ramp time
(
0.000 s
In order to reduce jerking, the two ramps can be set in
such a way that they are s-shaped. This is done by
entering a relative S-ramp time.