C02581 | holding brake: speed thresholds, C02582 | holding brake: setting, C02582 – Lenze 8400 HighLine User Manual
Page 1128: C02581/1, C02581/2, C02581/3, C02581/4, C02581/5, C02582/bit 4, Selection of
15
Parameter reference
15.2
Parameter list | C02581
1128
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02581
C02582
Parameter | Name:
C02581 | Holding brake: Speed thresholds
Data type: INTEGER_16
Index: 21994
d
= 55EA
h
Speed setpoint threshold and hysteresis for automatic holding brake control
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C02581/1
5.00 %
Holding brake: Switching threshold
• Switching threshold of the speed setpoint from which
on the holding brake is released/applied
automatically.
C02581/2
1.00 %
Holding brake: Hyst.release
• Hysteresis for holding brake release.
• Release threshold = switching threshold + release
hysteresis
C02581/3
1.00 %
Holding brake: Hyst. close
• Hysteresis for holding brake application.
• Application threshold = switching threshold -
application hysteresis
C02581/4
0.00 %
Holding brake: FF control starting value 1
•
From version 06.00.00
C02581/5
0.00 %
Holding brake: FF control starting value 2
•
From version 06.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02582 | Holding brake: Setting
Data type: UNSIGNED_8
Index: 21993
d
= 55E9
h
Activation of functional holding brake control options
Setting range
(min. hex value | max. hex value)
Lenze setting
0x00
0xFF 0x40 (decimal: 64)
Value is bit-coded: ( = bit set)
Info
Bit 0 bMBrakeReleaseOut invert.
Activation of inverted control
• 1 ≡ Inverted logic of the control signal for the holding
brake control switching element.
Bit 1 Horizontal brake protection
Brake response in case of pulse inhibit
• 1 ≡ In the case of a pulse inhibit, the actual speed
value is monitored which must reach the "Close"
threshold value to cause the holding brake to be
applied.
Note:
• This function is only active if bit 3
(horizontal/winding technology) is set as well. The
function is used in order that, when the controller is
inhibited, the holding brake of a drive with horizontal
traverse path does not wear out during rotation.
• With vertical motion (bit 3 = 0), this function is not
active. Especially with hoists and activated pulse
inhibit of the controller, an immediate application of
the brake is essential for safety-related reasons!