7 delete logbook, 8 device search function, Delete logbook – Lenze 8400 HighLine User Manual
Page 110: Device search function, 4device control (dctrl)
4
Device control (DCTRL)
4.1
Device commands (C00002/x)
110
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.7
Delete logbook
The
= "1: On / start" device command deletes all logbook entries.
Tip!
To display the logbook in the »Engineer«, click the Logbook button on the Diagnostics tab.
In the Logbook dialog box, it is also possible to delete all logbook entries by clicking the
Delete button.
Detailed information on the logbook can be found in the "
4.1.8
Device search function
This function extension is available from version 06.00.00!
In some applications where controllers are installed in control cabinets or are positioned in a
spacious plant, it is often difficult to locate a device connected online for e.g. maintenance work.
There is an established online connection with the device but you do not know where the controller
is located physically.
The
= "1: On / start" device command serves to carry out an "optical location":
, all four status LEDs at the front of the controller flash. Afterwards,
the function is turned off automatically.
• If the device command is executed again within the set time period, the duration is extended
accordingly.
• The setting
= "0: Off / ready" serves to abort or switch off the function.
• Adjustable time period: 0 ... 6000 s (Lenze setting: 5 s)
Tip!
The device search function can also be activated via the
toolbar icon.