C00252 | l_dt1_1: gain, C00253 | l_dt1_1: sensitivity, C00254 | kp position controller – Lenze 8400 HighLine User Manual
Page 859: C00270 | sc: freq. current setpoint filter, C00270, C00254, 15 parameter reference
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
859
15
Parameter reference
15.2
Parameter list | C00252
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00252
C00253
C00254
C00265
C00270
Parameter | Name:
C00252 | L_DT1_1: Gain
Data type: INTEGER_16
Index: 24323
d
= 5F03
h
FB
: Gain factor Vp
Setting range
(min. value | unit | max. value)
Lenze setting
-320.00
320.00 1.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00253 | L_DT1_1: Sensitivity
Data type: UNSIGNED_8
Index: 24322
d
= 5F02
h
FB
: Selection of sensitivity
• Depending on the selection, the number of indicated higher-order bits is evaluated.
Note:
The most significant bit determines the sign of the value, the remaining bits determine the numerical value.
Selection list
(Lenze setting printed in bold)
Info
1 15 bits
Bit 0 ... bit 14 are evaluated
2 14 bits
Bit 0 ... bit 13 are evaluated
3 13 bits
Bit 0 ... bit 12 are evaluated
4 12 bits
Bit 0 ... bit 11 are evaluated
5 11 Bit
Bit 0 ... bit 10 are evaluated
6 10 Bit
Bit 0 ... bit 9 are evaluated
7 9 Bit
Bit 0 ... bit 8 are evaluated
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00254 | Kp position controller
Data type: UNSIGNED_16
Index: 24321
d
= 5F01
h
Gain for following error compensation
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
1/s
500.00 5.00 1/s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00265 | SLVC: Tn torque controller
Data type: UNSIGNED_8
Index: 24310
d
= 5EF6
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00270 | SC: Freq. current setpoint filter
Data type: UNSIGNED_16
Index: 24305
d
= 5EF1
h
Frequency to be inhibited by the current setpoint filter at servo control (
) and sensorless control for synchronous
motors (
Setting range
(min. value | unit | max. value)
Lenze setting
40.0
Hz
1000.0 200.0 Hz
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10