363
6
I/O terminals
6.6
User-defined terminal assignment
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.6.2
Changing the terminal assignment with the keypad
You can reconfigure the preconfigured terminal assignment with the keypad (and with the
»Engineer«) by means of so-called configuration parameters.
• Each configuration parameter represents a signal input of a system block or application block.
• Each configuration parameter contains a selection list with output signals of the same type of
data.
• Logical linking is thus carried out by selecting the output signal for the corresponding signal
input.
In the following example, digital output 1 (LS_DigitalOutput.bOut1 input) is logically linked to the
status signal "Drive ready" (LA_nCtrl_bDriveReady output signal):
Configuration parameters for the analog and digital output terminals
The preconfigured assignment of the analog and digital output terminals can be altered by means
Other subcodes (not shown here) allow the configuration of input signals of different system blocks
and port blocks.
Parameter
Info
Lenze setting
Value Unit
Analog outputs - terminal assignment
LS_AnalogOutput: nOut1_a (V)
1003: LA_nCtrl_nMotorSpeedAct_a
LS_AnalogOutput: nOut1_a (I)
0: Not connected
LS_AnalogOutput: nOut2_a (V)
0: Not connected
LS_AnalogOutput: nOut2_a (I)
0: Not connected
Digital outputs - terminal assignment
LS_DigitalOutput:bRelay
1001: LA_nCtrl_bDriveFail
LS_DigitalOutput:bOut1
1000: LA_nCtrl_bDriveReady
LS_DigitalOutput: bOut2
0: Not connected
LS_DigitalOutput: bOut3
0: Not connected
LS_DigitalOutput: bOut HighCurrent
0: Not connected