6 ac drive profile diagnostic parameters, 7 setting parameters (short overview), Ac drive profile diagnostic parameters – Lenze 8400 HighLine User Manual
Page 423: Setting parameters (short overview), 7technology applications
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
423
7
Technology applications
7.3
TA "actuating drive speed (AC Drive Profile)"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.6
AC Drive Profile diagnostic parameters
In the All parameters tab, the parameters for diagnostic purposes listed in the following table are
displayed in the AC Drive Profile category.
7.3.7
Setting parameters (short overview)
Note!
These parameter are set by the EtherNet/IP™ communication module and should not be
written by the user.
Parameter
Info
Lenze setting
ACDrive: DriveMode
1: Speed mode
ACDrive: Control word
-
ACDrive: Status word
-
ACDrive: Speed scaling
0
ACDrive: Torque scaling
0
Highlighted in grey = display parameter
Parameter
Info
Lenze setting
Value Unit
Accel. time - main setpoint
2.000 s
Decel. time - main setpoint
2.000 s
Auto-DCB: Threshold
3 rpm
LS_DriveInterface: bNActCompare
0.00 %
DCB braking: Current
50.00 %
Fixed setpoint 1
40.00 %
Fixed setpoint 2
60.00 %
Fixed setpoint 3
80.00 %
Fixed setpoint 4 ... 15
0.00 %
Add. accel. time 1 ... 15
0.000 s
Add. decel. time 1 ... 15
0.000 s
Decel. time - quick stop
2.000 s
Auto-DCB: Hold time
0.500 s
DCB braking: Hold time
999.000 s
L_NSet_1: Ramp smoothing
0: Off
L_NSet_1: S-ramp time PT1
20.00 s
L_NSet_1: Setpoint arithmetic
0: Out = Set
L_NSet_1: Acceleration time - add. setpoint
0.000 s
L_NSet_1: Deceleration time - add. setpoint
0.000 s
L_PCTRL_1: Vp
1.0
L_PCTRL_1: Tn
400 ms
L_PCTRL_1: Kd
0.0