Xx.0184.00001, Xx.0145.00035, Xx.0145.00050 – Lenze 8400 HighLine User Manual
Page 662: Xx.0145.00051, Xx.0145.00052, 9diagnostics & error management
9
Diagnostics & error management
9.9
Error messages of the operating system
662
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
dF10: AutoTrip reset [xx.0145.00035]
dF50: Retain error [xx.0145.00050]
dF51: CuCcr error [xx.0145.00051]
dF52: BuCcr error [xx.0145.00052]
Ck01: Pos. HW limit switch [xx.0184.00001]
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Too frequent auto-trip reset.
• Check the error cause that activates the auto-trip
reset.
• Eliminate error cause and reset (acknowledge) error
manually afterwards.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
An error has occurred when accessing retain data.
• Either caused by an internal hardware error or by lack
of mains switching after a firmware download.
Mains switching
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Device error
Mains switching
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Device error
Mains switching
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: The hardware limit switch in positive traversing
direction has tripped.
• The bLimitSwitchPos input for travel range
monitoring via positive hardware limit switch has
been set to FALSE (fail-safe).
Reset error message and retract limit switch.