C01091 | ls_parreadwrite 1-6: cycle time, C01092 | ls_parreadwrite 1-6: failstate, 15 parameter reference – Lenze 8400 HighLine User Manual
Page 1054
15
Parameter reference
15.2
Parameter list | C01091
1054
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01091
C01092
Parameter | Name:
C01091 | LS_ParReadWrite 1-6: Cycle time
Data type: UNSIGNED_16
Index: 23484
d
= 5BBC
h
From version 04.00.00
Time interval for cyclic reading/writing
Selection list
0 0 (by Execute)
20 20 ms
50 50 ms
100 100 ms
200 200 ms
500 500 ms
1000 1 s
2000 2 s
5000 5 s
10000 10 s
Subcodes
Lenze setting
Info
C01091/1
0: 0 (by Execute)
: Cycle time
C01091/2
0: 0 (by Execute)
: Cycle time
C01091/3
0: 0 (by Execute)
: Cycle time
C01091/4
0: 0 (by Execute)
: Cycle time
C01091/5
0: 0 (by Execute)
: Cycle time
C01091/6
0: 0 (by Execute)
: Cycle time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01092 | LS_ParReadWrite 1-6: FailState
Data type: UNSIGNED_16
Index: 23483
d
= 5BBB
h
From version 04.00.00
Error status:
• 0 = no error
• 33803 | 0x840B = invalid data type (e.g. STRING)
• 33804 | 0x840C = limit violation
• 33806 | 0x840E = invalid code
• 33813 | 0x8415 = no element of the selection list
• 33815 | 0x8417 = writing of the parameter not permitted
• 33816 | 0x8418 = writing of the parameter only permitted if controller is inhibited
• 33829 | 0x8425 = invalid subcode
• 33865 | 0x8449 = no parameter with subcodes
Display range
(min. value | unit | max. value)
0
34000
Subcodes
Info
C01092/1
: Error status
C01092/2
: Error status
C01092/3
: Error status
C01092/4
: Error status
C01092/5
: Error status
C01092/6
: Error status
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1