15
Parameter reference
15.2
Parameter list
796
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
15.2
Parameter list
This chapter lists all parameters of the operating system in numerically ascending order.
C00001
Note!
The parameter descriptions are based on the software version V15.00.00.
Parameter | Name:
C00001 | Keypad Userlevel
Data type: UNSIGNED_8
Index: 24574
d
= 5FFE
h
From version 12.00.00 onwards
, the extent of menus, submenus and codes shown in the keypad can be adapted by
selecting the "userlevel".
• When the userlevel has been changed, the menus of the keypad will be reconfigured according to the selected
user level.
• Independently of the set userlevel, the parameters of the attached communication module will always be
displayed completely.
Selection list
Info
10 Standard
Only the most important menus and codes are displayed
on the keypad.
20 Expert
All menus and codes are displayed on the keypad.
30 Service
Only for servicing purposes (Lenze service).
Subcodes
Lenze setting
Info
C00001/1
10: Standard
Keypad UserLevel
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1