C01226 | mck: ref. s-ramp time, C01227 | mck: ref. positions, C01228 | mck: ref. sequence profile – Lenze 8400 HighLine User Manual
Page 1071: C01227/2, C01227/1, To preve, C01226/1, C01228, Et in, 15 parameter reference
![background image](/manuals/566310/1071/background.png)
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
1071
15
Parameter reference
15.2
Parameter list | C01226
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01226
C01227
C01228
Parameter | Name:
C01226 | MCK: Ref. S-ramp time
Data type: UNSIGNED_16
Index: 23349
d
= 5B35
h
S-ramp time for reference search/homing
• Setting "0 s" ≡ no rounding
Setting range
(min. value | unit | max. value)
0.000
s
10.000
Subcodes
Lenze setting
Info
C01226/1
0.000 s
MCK: Ref. S-ramp time
• S-ramp time for the starting and search speed ramps.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01227 | MCK: Ref. positions
Data type: INTEGER_32
Index: 23348
d
= 5B34
h
Positions for determining the zero position of the reference measuring system
Setting range
(min. value | unit | max. value)
-214748.3647
unit
214748.3647
Subcodes
Lenze setting
Info
C01227/1
0.0000 unit
MCK: Ref. offset reference degree
• Relative traverse path by which the drive traverses
correctly signed with search speed after detection of
the sensor reference signal.
C01227/2
0.0000 unit
MCK: Ref. home position
• Position with which setpoint and actual position are
loaded after completion of homing.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01228 | MCK: Ref. sequence profile
Data type: UNSIGNED_8
Index: 23347
d
= 5B33
h
Number of the sequence profile the absolute position of which will be approached after homing.
Setting range
(min. value | unit | max. value)
Lenze setting
0
15 0
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1