15 parameter reference – Lenze 8400 HighLine User Manual
Page 1170
15
Parameter reference
15.6
Table of attributes
1170
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Current password protection
Bit coded
24068
5E04
A
1
UNSIGNED_16
1
PW protection config X6(DIAG)
Bit coded
24067
5E03
A
1
UNSIGNED_16
1
PW protection config X1 (CAN)
Bit coded
24066
5E02
A
1
UNSIGNED_16
1
PW protection config. MCI
Bit coded
24065
5E01
A
1
UNSIGNED_16
1
User menu
Linear value
24058
5DFA
A
32
INTEGER_32
1000
Fan switching status
Selection list
24015
5DCF
A
2
UNSIGNED_8
1
Failure indication
Selection list
24014
5DCE
A
5
UNSIGNED_8
1
Resp. to mains phase failure
Selection list
24010
5DCA
E
1
UNSIGNED_8
1
Resp. to fan failure
Selection list
24009
5DC9
E
1
UNSIGNED_8
1
Resp. to speed controller limited
Selection list
24008
5DC8
E
1
UNSIGNED_8
1
Resp. to peak current
Selection list
24006
5DC6
A
1
UNSIGNED_8
1
Resp. to controller limitations
Selection list
24005
5DC5
A
4
UNSIGNED_8
1
Resp. to wrong controller setting
Selection list
24004
5DC4
A
2
UNSIGNED_8
1
Brake resistor overload threshold
Linear value
24003
5DC3
E
1
UNSIGNED_8
1
Resp. to brake resist. overtemp.
Selection list
24001
5DC1
E
1
UNSIGNED_8
1
SC: Optimisation of field feedforward
control
Linear value
23999
5DBF
E
1
UNSIGNED_16
1
SC: Vp field weakening controller
Linear value
23998
5DBE
E
1
UNSIGNED_16
10000
SC: Tn field weakening controller
Linear value
23997
5DBD
E
1
UNSIGNED_16
10
Resp. to max. speed/output freq. reached
Selection list
23996
5DBC
E
1
UNSIGNED_8
1
Resp. to operating system error
Selection list
23995
5DBB
A
1
UNSIGNED_8
1
Resp. to LS_SetError_x
Selection list
23994
5DBA
A
8
UNSIGNED_8
1
Resp. to heatsink temp.> shutdown temp.
-5°C
Selection list
23993
5DB9
E
1
UNSIGNED_8
1
Resp. to motor overtemp. PTC
Selection list
23990
5DB6
E
1
UNSIGNED_8
1
Resp. open circuit HTL encoder
Selection list
23989
5DB5
E
1
UNSIGNED_8
1
Resp. to max. speed at switching freq.
Selection list
23987
5DB3
E
1
UNSIGNED_8
1
Resp. to switch. frequency red.
Selection list
23985
5DB1
E
1
UNSIGNED_8
1
Resp. to CAN bus connection
Selection list
23983
5DAF
A
5
UNSIGNED_8
1
Resp. to CANx_IN monitoring
Selection list
23982
5DAE
A
4
UNSIGNED_8
1
Resp. to control word error
Selection list
23981
5DAD
A
2
UNSIGNED_8
1
MCK: Resp. to MCK error
Selection list
23980
5DAC
A
15
UNSIGNED_8
1
Resp. to motor phase failure
Selection list
23978
5DAA
E
1
UNSIGNED_8
1
Resp. to open circuit AINx
Selection list
23977
5DA9
A
2
UNSIGNED_8
1
Motor phase failure threshold
Linear value
23976
5DA8
E
1
INTEGER_16
100
Resp. to DC bus voltage
Selection list
23975
5DA7
A
1
UNSIGNED_8
1
Delayed resp. to fault: DC bus overvoltage Linear value
23974
5DA6
A
1
UNSIGNED_16
1000
Resp. to earth fault
Selection list
23973
5DA5
E
1
UNSIGNED_8
1
Resp. to device overload (Ixt)
Selection list
23971
5DA3
E
1
UNSIGNED_8
1
Resp. to feedback
Selection list
23970
5DA2
A
1
UNSIGNED_8
1
Resp. to motor overload (I²xt)
Selection list
23969
5DA1
E
1
UNSIGNED_8
1
Resp. to max. freq. feedb. DIG12/67
Selection list
23968
5DA0
E
1
UNSIGNED_8
1
Resp. to maximum torque
Selection list
23967
5D9F
E
1
UNSIGNED_8
1
Resp. to maximum current
Selection list
23966
5D9E
E
1
UNSIGNED_8
1
System connection list: 16-bit
Selection list
23955
5D93
A
111 UNSIGNED_16
1
System connection list: Bool
Selection list
23954
5D92
A
199 UNSIGNED_16
1
System connection list: Angle
Selection list
23953
5D91
A
25
UNSIGNED_16
1
L_Limit 1-2: Min/Max
Linear value
23945
5D89
A
4
INTEGER_16
100
L_LimitPhi 1-3: Min/Max
Linear value
23944
5D88
A
6
INTEGER_32
1
L_NSet_1: Max. skip freq.
Linear value
23943
5D87
A
3
INTEGER_16
100
L_NSet_1: Min. skip freq.
Linear value
23942
5D86
A
3
INTEGER_16
100
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Grayed out = display parameter (read access only)