2introduction: parameterising the controller – Lenze 8400 HighLine User Manual
Page 35
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
35
2
Introduction: Parameterising the controller
2.3
General notes on parameters
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Menu structure
In the keypad, the parameters are classified into various menus and submenus.
• The USER menu includes a selection of frequently used parameters.
• The Code list contains all parameters.
• The Go to param function enables you to reach the corresponding parameter directly.
• The Logbook logs all errors and their chronological history.
• The Diagnostics menu contains diagnostic/display parameters for displaying device-internal
process factors, current actual values and status messages.
Userlevel
From version 12.00.00 onwards
, the extent of menus, submenus an codes shown in the keypad can
be adapted by selecting the "Userlevel" in
• Userlevel Standard (Lenze setting): Only the most important menus and codes are shown in the
keypad.
• Userlevel Expert: All menus and codes are shown in the keypad.
• Userlevel Service: For service purposes only (Lenze service).
The the Userlevel has been changed, the menus are restructured in the keypad according to the
selected Userlevel. The parameters of a plugged in communication module are always displayed
completely independent of the set Userlevel.
Function - left function key
Function - right function key
Change parameter setting
(change to editing mode)
Accept change in the controller
(no saving with mains failure protection
)
Back to main menu
Abort (discard change)
Parameter can only be changed when the controller is inhibited
Save all parameter settings in the memory module safe against mains failure
Control elements
Execute the function assigned to the function key (see LCD display)
Execute the stop function set in
(Lenze setting: Inhibit controller)
Deactivate stop function again (Lenze setting: Enable controller again)
In the menu level: Select menu/submenu
In the parameter level: Select parameter
In the editing mode: Change marked digits or select list entry
In the menu level: Select submenu/change to parameter level
In the editing mode: Cursor to the right
In the menu level: One menu level higher (if available)
In the parameter level: Back to the menu level
In the editing mode: Cursor to the left
LCD display