beautypg.com

C01216 | mck: positioning setting, C01216, G in – Lenze 8400 HighLine User Manual

Page 1066: 15 parameter reference

background image

15

Parameter reference

15.2

Parameter list | C01216

1066

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01216

Parameter | Name:

C01216 | MCK: Positioning setting

Data type: UNSIGNED_8

Index: 23359

d

= 5B3F

h

From version 04.00.00

Positioning

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x01 (decimal: 1)

Value is bit-coded: (= bit set)

Info

Bit 0  PosAbort at PosInit

1 ≡ When a changeover to "positioning" mode is made,

ramping down at the rate of deceleration set in

C01251

for normal stopping is carried out.

Bit 1  PosExecute active at PosInit

1 ≡When a changeover is made to the "positioning"

mode, the specified profile is immediately executed if

the "MCK PosExecute" control bit has also been set. If the

MCK "PosExecute" control bit has not been set, the

setpoint is continued.

Bit 2 

Reserved

Bit 3 

Reserved

Bit 4  ProfilStart at PosInit

1 ≡When it is changed to the "Positioning" operating

mode, the defined profile is executed immediately

without the need to set the MCK control bit

"PosExecute".

Bit 5  Maximum jerk

1 ≡ The maximum jerk is calculated based on the

acceleration and S-ramp time of the current profile and

the sequence profile. This is then used in an accelerated

drive for reducing the acceleration to 0 or for

acceleration of the sequence profile.

From version 14.00.00

Setting or activation of maximum jerk for traversing

profiles

Bit 6 

Reserved

Bit 7 

Reserved