C01216 | mck: positioning setting, C01216, G in – Lenze 8400 HighLine User Manual
Page 1066: 15 parameter reference
15
Parameter reference
15.2
Parameter list | C01216
1066
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01216
Parameter | Name:
C01216 | MCK: Positioning setting
Data type: UNSIGNED_8
Index: 23359
d
= 5B3F
h
From version 04.00.00
Setting range
(min. hex value | max. hex value)
Lenze setting
0x00
0xFF 0x01 (decimal: 1)
Value is bit-coded: ( = bit set)
Info
Bit 0 PosAbort at PosInit
1 ≡ When a changeover to "positioning" mode is made,
ramping down at the rate of deceleration set in
for normal stopping is carried out.
Bit 1 PosExecute active at PosInit
1 ≡When a changeover is made to the "positioning"
mode, the specified profile is immediately executed if
the "MCK PosExecute" control bit has also been set. If the
MCK "PosExecute" control bit has not been set, the
setpoint is continued.
Bit 2
Reserved
Bit 3
Reserved
Bit 4 ProfilStart at PosInit
1 ≡When it is changed to the "Positioning" operating
mode, the defined profile is executed immediately
without the need to set the MCK control bit
"PosExecute".
Bit 5 Maximum jerk
1 ≡ The maximum jerk is calculated based on the
acceleration and S-ramp time of the current profile and
the sequence profile. This is then used in an accelerated
drive for reducing the acceleration to 0 or for
acceleration of the sequence profile.
•
From version 14.00.00
Setting or activation of maximum jerk for traversing
Bit 6
Reserved
Bit 7
Reserved
Read access Write access CINH PLC STOP No transfer COM MOT