C01073 | l_dfset_1: adjustment, C01074 | l_dfset_1: zero pulse divider, 15 parameter reference – Lenze 8400 HighLine User Manual
Page 1048
![background image](/manuals/566310/1048/background.png)
15
Parameter reference
15.2
Parameter list | C01073
1048
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01073
C01074
Parameter | Name:
C01073 | L_DFSET_1: Adjustment
Data type: UNSIGNED_8
Index: 23502
d
= 5BCE
h
From version 11.00.00
Setting range
(min. hex value | max. hex value)
0x00
0xFF
Value is bit-coded:
Info
Bit 0 Setpoint angle without gearbox
factor
0 ≡ Evaluation of the setpoint angle with gearbox factor
1 ≡ Evaluation of the setpoint angle without gearbox
factor
Bit 1 Angle correction with polynomial
0 ≡ Angle correction without downstream polynomial
1 ≡ Angle correction with downstream polynomial
Bit 2 External angle correction
0 ≡ Internal angle correction
1 ≡ External angle correction
•
From version 13.00.00
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Subcodes
Lenze setting
Info
C01073/1
0x02
: Adjustment
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C01074 | L_DFSET_1: Zero pulse divider
Data type: UNSIGNED_16
Index: 23501
d
= 5BCD
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
0
16384
Subcodes
Lenze setting
Info
C01074/1
0
: Divider for actual value zero pulse
C01074/2
0
: Divider for setpoint zero pulse
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1