C00509 | pw protection config x1(can), C00509/1, 15 parameter reference – Lenze 8400 HighLine User Manual
Page 911
![background image](/manuals/566310/911/background.png)
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
911
15
Parameter reference
15.2
Parameter list | C00509
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00509
Parameter | Name:
C00509 | PW protection config X1(CAN)
Data type: UNSIGNED_16
Index: 24066
d
= 5E02
h
From version 15.00.00
Configuration of the password protection for parameter access via CANopen interface X1 ("CAN on board")
Individual password protection for single communication channels
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0
Reserved
Bit 1 Parameter write protection
The CANopen interface X1 cannot be used to write into
write/read parameters.
Bit 2 Parameter read protection
The CANopen interface X1 cannot be used to read
write/read parameters.
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Lenze setting
Info
C00509/1
0x0006
PW protection config X1 (CAN)
Read access Write access CINH PLC STOP No transfer COM MOT