Duplicating/deleting density balance data – Konica Minolta bizhub PRESS C8000e User Manual
Page 403
bizhub PRESS C8000/e
9-85
9.11
[04 Density Balance Adjustment]
9
21
When the adjustment is completed, press [OK] on the Density Balance Manual Setting Screen.
NOTICE
Without a chart output after making an adjustment, pressing [OK] on the Density Adjustment Manual
Setting Screen will not function for the data to be changed and registered. Be sure to output a chart
after making an adjustment, then press [OK].
The Density Balance Adjustment Data Register/Delete Screen will be restored, with [NEW PROFILE]
displayed in the [Adj. Data Profile Name] field.
22
Press [Change Name].
The Change Profile Name Screen will be displayed.
% Enter the desired profile name, then press [OK].
23
Press [Return] to restore the Density Balance Adjustment Menu Screen.
Duplicating/Deleting density balance data
Follow the procedure below to duplicate or delete the density balance data.
-
Duplication is unavailable if 10 pieces of adjustment data has already been registered. Delete one from
the list, if desired.
1
Press [Adjustment] on the Machine Screen to display the Adjustment Menu Screen.
2
Press [04 Density Balance Adjustment] and [02 Density Balance Data Reg/Del] in sequence.
The Density Balance Adjustment Data Register/Delete Screen will be displayed.
3
Select the desired number of row from the 10 on the list.