Konica Minolta bizhub PRESS C8000e User Manual
Page 380
9.8
[03 Finisher Adjustment] (Perfect Binder PB-503)
9
bizhub PRESS C8000/e
9-62
1
Press [Adjustment] on the Machine Screen to display the Adjustment Menu Screen.
2
Press [03 Finisher Adjustment], [07 Perfect Binder Adjustment], and [09 Cover Up/Down CD Width Adj.]
in sequence.
The Cover Up/Down CD Width Adjustment Screen will be displayed.
3
Load cover sheets in either cover tray of perfect binder or any other tray.
4
Load paper for body sets in the desired tray.
5
Select either [Perfect Binder Tray] or [Except PB Tray] for the tray loaded with covers.
6
Press [Print Mode].
7
Select the tray key loaded with paper for body sets.
8
Press Start on the control panel. A sample pattern of perfect-bound book will be output.
9
Check that the horizontal scanning position of body set matches with that of the cover.
10
If any adjustment is required, press [Exit Print Mode] to return to the Cover Up/Down CD Width Adjust-
ment Screen.
11
Use the touch panel keypad or control panel keypad to enter the setting data.
% Use [+/-] to specify the value to be positive or negative.
% Press [Set] to change the current data.
% Adjustable range: -20 (Wide) to +20 (Narrow) (1 step = 0.1 mm)
% If desired, display the help message to view details of the adjustment you made.
12
Repeat the steps from 6 to 11 until the desired result is obtained.
13
Press [Return] to restore the Perfect Binder Adjustment Menu Screen.
9.8.10
[07 Perfect Binder Adjustment] - [10 Clamp FD Position Adj.]
Change the adjustment width in paper feed direction if body pages show misalignment using Perfect Binder
PB-503. The sizes referred to in this section are those of body sets corresponding to cover sizes.
Objects of adjustment: Full Area, A4 v, B5 v, A5 w/v, 8.5 e 11 v, 5.5 e 8.5 v, 16K v, Custom (220-379 mm),
Custom (148-219 mm)
NOTICE
With [Full Area] selected, the entered value will be applied to all sizes. With a specific paper size selected, set
value will be the sum of the entered value and the value previously specified for [Full Area].