7 [02 scan adjustment] - [03 fd-mag. adjustment, 02 scan adjustment] - [03 fd-mag. adjustment] -18 – Konica Minolta bizhub PRESS C8000e User Manual
Page 336

9.2
[01 Machine Adjustment]
9
bizhub PRESS C8000/e
9-18
10
Use the touch panel keypad or control panel keypad to enter the setting data.
% Use [+/-] to specify the value to be positive or negative.
% Press [Set] to change the current data.
% Adjustable range: ADF Centering-Front, ADF Centering-Back -60 (Front) to +60 (Back) (1 step = 0.1
mm) Adjustable range: Orig. Glass Centering -30 (Front) to +30 (Back) (1 step = 0.1 mm)
11
Repeat the steps from 4 to 10 until the desired result is obtained.
12
Press [Return] to restore the Scan Adjustment Menu Screen.
9.2.7
[02 Scan Adjustment] - [03 FD-Mag. Adjustment]
Adjust the magnification in paper feed direction when scanning the original from the original glass.
NOTICE
Make this adjustment after completing [01 Machine Adjustment] - [01 Printer Adjustment] - [03 FD-Mag. Ad-
justment].
1
Press [Adjustment] on the Machine Screen to display the Adjustment Menu Screen.
2
Press [01 Machine Adjustment], [02 Scan Adjustment], and [03 FD-Mag. Adjustment] in sequence.
The FD-Mag. Adjustment Screen will be displayed.
3
Press [Print Mode].
4
Load A3 w paper into a tray, then select that tray key.
5
Place the test chart on the original glass, then press Start on the control panel. A sample pattern will
be output.
6
Check the misalignment by comparing the original and the output.
Allowance: 0 +/- 0.5% or less (full size)
Within 205.7 +/- 1 mm
7
If any adjustment is required, press [Exit Print Mode] to return to the FD-Mag. Adjustment Screen.
8
Use the touch panel keypad or control panel keypad to enter the setting data.
% Use [+/-] to specify the value to be positive or negative.
% Press [Set] to change the current data.
% Adjustable range: -40 (Short) to +40 (Long) (1 step = 0.05%)
9
Repeat the steps from 3 to 8 until the desired result is obtained.
10
Press [Return] to restore the Scan Adjustment Menu Screen.