Modifying a snmp community – Allied Telesis AT-S60 User Manual
Page 76

AT-S60 Management Software User’s Guide
Section II: Local and Telnet Management
75
Modifying a SNMP Community
Use this procedure to change the attributes of a SNMP community.
1. From the Main Menu, type 5 to select System Menu.
The System Menu is shown in Figure 5 on page 47.
2. From the System Menu, type 1 to select Configure System.
The Configure System Menu is shown in Figure 9 on page 52.
3. From the Configure System Menu, type 1 to select Configure System
Software.
The Configure System Software Menu is shown in Figure 10 on
page 53.
4. From the Configure System Software Menu, type 8 to select
Configure SNMP.
The Configure SNMP Menu is shown in Figure 17 on page 70.
5. Select 3 - Configure SNMP Community to configure SNMP
parameters.
The Configure SNMP Community menu is shown in Figure 18 on
page 71.
6. Select 3 - Modify SNMP Community.
The Modify SNMP Community menu is shown in Figure 19.
Figure 19 Modify SNMP Community Menu
Allied Telesyn AT-8400 Series - ATS60 V2.0.0
High School Switch 142
User: Manager
00:14:33 15-Jan-2003
Modify SNMP Community
Community Name
Access Mode
Status
OpenAcc
Manager IP Address
Trap Receiver IP
====================================================================================
private
Read|Write
Enabled
No
147.35.18.85
public
Read Only
Enabled
No
147.35.18.86
1 - Add Attributes to Community
2 - Delete Attributes from Community
3 - Set Community Access Mode
4 - Set Community Status
5 - Set Community Open Access
U - Update Display
R - Return to Previous Menu
Enter your selection?