Allied Telesis AT-S60 User Manual
Page 419

Chapter 25: 802.1x Port-Based Access Control
Section III: Security Features
418
❑ Force-unauthorized: Causes the port to remain in the
unauthorized state, ignoring all attempts by the client to
authenticate. The switch cannot provide authentication services
to the client through the interface
2 - Quiet Period
Sets the number of seconds that the switch remains in the quiet
state following a failed authentication exchange with the clien
t.
The default value is 60 seconds. The range is 0 to 65,535 seconds.
3 - Tx Period
Sets the number of seconds the switch waits for the EAP-
request/identity frame response from the supplicant before
retransmitting the request. The default value is 30 seconds. The
range is 1 to 65,535 seconds.
4 - Reauth Period
Enables periodic re-authentication of the client, which is disabled
by default. The default value is 3,600 seconds. The range is 1 to
65,535 seconds.
5 - Supplicant Timeout
Sets the switch-to-client retransmission time for the EAP-request
frame. The default value is 30 seconds. The range is 1 to 600
seconds.
6 - Server Timeout
This is the timer used by the switch to determine authentication
server timeout conditions. The default value is 30 seconds. The
range is 1 to 65,535 seconds.
7 - Max Requests
This parameter specifies the maximum number of times that the
switch retransmits an EAP Request packet to the client before it
times out the authentication session. The default value is 2
retransmissions. The range is 1 to 10 retransmissions.
7. After making changes, type R until you return to the Main Menu. Then
type S to select Save Configuration Changes.