Enter the show interface interface_type rbridge_id/slot/port command to display the configuration
details for the specified interface.

switch# show interface tengigabitethernet 1/1/9

tengigabitethernet 1/1/9 is up, line protocol is up (connected)

Hardware is Ethernet, address is 0005.3315.df5a

Current address is 0005.3315.df5a

Pluggable media present

Interface index (ifindex) is 4702109825

MTU 9216 bytes

LineSpeed Actual : 10000 Mbit

LineSpeed Configured : Auto, Duplex: Full

Flowcontrol rx: off, tx: off

Priority Tag disable

Last clearing of show interface counters: 04:12:03

Queueing strategy: fifo

Receive Statistics:

1580 packets, 140248 bytes

Unicasts: 0, Multicasts: 1580, Broadcasts: 0

64-byte pkts: 0, Over 64-byte pkts: 1561, Over 127-byte pkts: 17

Over 255-byte pkts: 2, Over 511-byte pkts: 0, Over 1023-byte pkts: 0

Over 1518-byte pkts(Jumbo): 0

Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0

Errors: 0, Discards: 0, TrillportCtrlFrames: 1564

Transmit Statistics:

1583 packets, 140120 bytes

Unicasts: 0, Multicasts: 1583, Broadcasts: 0

Underruns: 0

Errors: 0, Discards: 0, TrillportCtrlFrames: 1583

Rate info (interval 299 seconds):

Input 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate

Output 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate

Time since last interface status change: 00:15:53

Refer also to

Slot numbering and configuration

on page 61.

Displaying slots and module status information

Use the show slots command to display information for all slots in the chassis. The following example
shows slot information for the Brocade VDX 8770-8.

switch# show slots

Slot Type Description ID Status

---------------------------------------------------------------------------

M1 MM Management Module 112 ENABLED

M2 MM Management Module 112 ENABLED

S1 SFM Switch Fabric Module 113 ENABLED

S2 VACANT@

S3 SFM Switch Fabric Module 113 ENABLED#

S4 SFM Switch Fabric Module 113 ENABLED#

S5 SFM Switch Fabric Module 113 ENABLED

S6 SFM Switch Fabric Module 113 ENABLED

L1 VACANT

L2 VACANT

L3 LC48X10G 48-port 10GE card 114 DIAG RUNNING POST1

L4 LC48X10G 48-port 10GE card 114 ENABLED

L5 VACANT

L6 VACANT

L7 LC48X1G 48-port 1GE card 114 ENABLED

L7 VACANT

L8 VACANT

# = At least one enabled SFM in these slots is required.

@ = The SFM Optical Switch is open.

Alternatively, you can use the following commands to display slots per module type:

• Use the show mm command to display information for the management modules.
• Use the show sfm command to display information for the switch fabric modules.
• Use the show linecard command to display information for the line cards.

To make the slot configuration persistent across a chassis reboot (which involves reloading the
management modules), you must save the configuration persistently by issuing the copy running-

Displaying slots and module status information

Network OS Administrator’s Guide

83