Packet counter samples, Hardware support matrix for sflow – Brocade Network OS Administrator’s Guide v4.1.1 User Manual
Page 526

Packet counter samples
A polling interval defines how often the sFlow octet and packet counter for a specific interface are sent
to the sFlow collector, but the sFlow agent is free to schedule the polling in order to maximize internal
efficiency.
Hardware support matrix for sFlow
The following table identifies Brocade VDX 8770 and VDX 67xx device support for specific sFlow
features.
sFlow feature support
TABLE 87
Feature
Brocade VDX 8770
Brocade VDX 67xx
sFlow global configurations for
enabling sFlow, polling interval,
collector, and sample rate
All are supported
All are supported
sFlow data source interface
Supports 1-Gbps, 10-Gbps, and 40-
Gbps interfaces
Supports 10-Gbps interfaces only
sFlow data source: Front port
trunks and VLANs
Not supported
Not supported
sFlow scanning for inbound,
outbound, or both directions on a
port
Supports inbound only
Supports inbound only
sFlow counter polling support on
per-port, per-VLAN, or per-trunk
basis
Supports only per-port counter
polling
Supports only per-port counter
polling
All standard if_counters and
Ethernet counters
Supported
Supported
Multiple collector configuration
A maximum of five collectors can be
configured.
A maximum of five collectors can be
configured.
Extended Gateway, Extended
router, and NAT/MPLS/URL header
formats
Not supported
Not supported
Subagent-ID
Filled with slot number of the
interface
Filled with a zero (0)
Agent IP address
Preference 1: Chassis IP
Preference 2: Management CP IP
Management IP
Maximum packets per second
272 pkts/sec/ASIC
VDX 8770-4: 6528 pkts/sec
VDX 8770-8: 13056 pkts/sec
96 pkts/sec/ASIC. Each ASIC
supports eight front-user ports on
the 48x10G and 48x1G line cards,
and supports two front-user ports on
the 12x48G Line card.
Packet counter samples
526
Network OS Administrator’s Guide