Brocade Network OS Administrator’s Guide v4.1.1 User Manual
Page 236
• Fan
• Power supply
• CID card
• SFP
• Line card
Possible states for all monitored FRUs are removed, inserted, on, off, and faulty. A state of none
indicates the switch is not configured. If the FRU is removed, inserted, or goes into a faulty state,
System Monitor sends a RASLog message or an e-mail alert, depending on the configuration.
Based on the configured threshold, each component can be in a marginal state or a down state. If a
component is in a marginal state or a down state, System Monitor generates a RASLog message to
alert the user. It also generates a separate RASLog message for the overall health of the switch.
NOTE
For details about each RASLog message, refer to the "RAS System Messages" chapter of the
Network OS Message Reference.
The following table lists the default threshold settings for components monitored by System Monitor on
supported switches.
Hardware platform default settings for supported switches
TABLE 37
Platform
Hardware component Default setting Marginal
thresholds
Down thresholds
Brocade VDX 6710
Power supply
2
1
2
Temperature sensor
3
1
2
Compact flash
1
1
0
Fan
2
1
2
Brocade VDX 6720-24 single
board 24-portswitch
Power supply
2
1
2
Temperature sensor
3
1
2
Compact flash
1
1
0
Fan
2
1
2
Brocade VDX 6720-60 single
board 60-portswitch
Power supply
2
1
2
Temperature sensor
6
1
2
Compact flash
1
1
0
Fan
5
1
2
Brocade VDX 6730-32
Power supply
2
1
2
Temperature sensor
3
1
2
Compact flash
1
1
0
Using System Monitor and Threshold Monitor
236
Network OS Administrator’s Guide
53-1003225-04