Factory thresholds for SFP types and monitoring areas (Continued)

TABLE 41

SfpType

Area

Default Value

TXP (µW)

1000

60

Current (mA)

12

2

1 GLR

Temperature (C)

90

-45

Voltage (mV)

3700

2900

RXP (µW)

501

6

TXP (µW)

794

71

Current (m)

45

1

10 GSR

Temperature (C)

90

-5

Voltage (mVolt)

3600

3000

RXP (µW)

1000

32

TXP (µW)

794

251

Current (mA)

11

4

10 GLR

Temperature (C)

88

-5

Voltage (mV)

3600

2970

RXP (µW)

1995

16

TXP (µW)

1585

158

Current (mA)

85

15

10 GUSR

Temperature (C)

100

-5

Voltage (mV)

3600

2970

RXP (µW)

2000

32

TXP (µW)

2000

126

Current (mA)

11

3

QSFP

Temperature (C)

75

-5

Voltage (mV)

3600

2970

RXP (µW)

1995

40

TXP (µW)

0

0