• Recover BAD from GOOD. This option is offered only if one CID card contains good data and the
other card contains corrupt data. If you select this option, cidrecov copies the good data onto the
affected card.
• Recover CID 2 from CID 1 and Recover CID 1 from CID 2. These options are offered only if the
data on both CID cards is good but there is a mismatch. You can select which card to use to
overwrite data on the other card.
The following is an example of running the cidrecov tool, receiving errors that can be fixed, and
selecting the Recover BAD from GOOD option (note that the example below contains only some of the
actual output):
sw0# cidrecov
CID 1 Non-Critical Seeprom is Inaccessible or Corrupted.
CID Non-Critical Seeprom Problem Details
CID 1 Non-Critical Seeprom IP address Control Data Checksum Bad !!!!
CID Recovery Options
0. Exit
1. Recover with default values
2. Recover BAD from GOOD
Enter Selection > 2
Copy IP Data table...
Copy 384 bytes from CID 2 to CID 1, num blks 1 resid 128
Read block 1 from CID 2 succeeded
Write block 1 to CID 1 succeeded
Read last block from CID 2 succeeded
Write last block to CID 1 succeeded
copy successful
Copy succeeded for all data types attempted
IP Address CID Recovery completed.
Understanding CID card failure
If the critical SEEPROM of a CID card contains any errors, or if the noncritical SEEPROM cannot be
read, then recovery is not possible and the following message is displayed:
Recovery is not possible. Please contact Brocade Technical Support for replacement of
the inaccessible CID(s).
Understanding CID card failure
Network OS Administrator’s Guide
665